Concrete Scanning in Austin: Slab Scan Before Cutting
Our GPR concrete scan of an office slab in north Austin found a post-tension cable and two other embedded features before saw cutting and coring. Here is what the scan showed and how the results were handed off to the cutting crew.
The project
A concrete cutting contractor needed a slab cleared before saw cutting and core holes for new electrical work in an upper-floor office suite in north Austin, part of an interior build-out. The scope called for two 10-ft trench areas in the slab, pre-marked by the client, to be checked for post-tension cables, rebar and any utilities embedded in the concrete. Hitting a tensioned cable or a live conduit during a cut is the kind of mistake that stops a job, so the areas had to be scanned first.
Our approach
In October 2026 our technician scanned each pre-marked area with a GSSI concrete scanner, using ground penetrating radar (GPR) in passes across each area. Hyperbolas and linear reflectors in the radargram indicate embedded objects such as cables, rebar or conduit.
Detected features were marked on site with paint and flags where the surface allowed. The floor covering had just been removed and the slab surface was still tacky, which made marking difficult, so the report asked the crew to re-check any faded marks before cutting. Site photos and radargram screenshots saved on the scanner documented the work.
What we found
- Area 1 (taped box near the exterior windows): a post-tension cable was detected. A second feature that appeared to be electric was also noted. Its type was not confirmed, so it was reported as a possible live electrical line.
- Area 2 (doorway between metal studs): an embedded feature was detected, but its type could not be determined. It was reported as unidentified.
- Area 3: no embedded features were detected, and the area was reported clear to proceed.
The saved radargrams show several shallow point reflections roughly 1 to 1.5 in below the surface, consistent with embedded cables or bars near the top of the slab, plus a steeply dipping linear reflection. GPR cannot confirm exactly what a detected object is, so the marks on site, not the screenshots, are what the cutting crew works from.
Before cutting or coring, the crew was told to avoid the marked post-tension cable and the possible electric line in Area 1, and the unidentified feature in Area 2. Post-tension cables are under high tension, and cutting one can cause serious injury and structural damage.
Deliverables
- Detected features marked on site with paint and flags
- Written report (Word and PDF) with project details, findings, GPR radargram screenshots and site photos
Cutting or coring a slab in Austin?
Scanning before the saw starts lets the crew plan cuts and cores around tendons and conduit. See our concrete scanning services, or visit our Austin utility locating page for work across Central Texas. For an outdoor job in the same city, read our northwest Austin fiber install write-up, and find more examples on our utility locating projects page.